30-minute Interior doors have two options; Hung doors, or Double Acting (door swings both ways) both available as single leaf or pair. Doors are supplied as a complete interior fire, smoke and acoustic door set, including door leaf, door jamb, seals and, when requested, appropriate hardware.
To achieve fire rating, fire doors must be self-closing and self-latching. Hardware must be selected from the approved hardware list.
Doors come factory sealer coated as standard, ready for priming and painting, and can also be supplied unsealed with a specified overlay (wood veneer, laminate, vinyl or metal). Inlay panels can also be affixed on request, to suit heritage buildings. There are also options for glazing panels, and overhead or sidelights.
Refer to data sheets for door thickness and leaf sizes.
Due to their solid core NZFD fire doors can achieve up to STC 34 (acoustic rating) if installed with appropriate perimeter seals.
30 Minute Fire-rated Interior Doors supplied by NZ Fire Doors Limited complies with the requirements of NZS 4520 Fire-resistant door sets when installed in accordance with NZ Fire Doors Installation Instructions into a complying fire-resistant wall, and when fitted with approved hardware.
Such compliance will be evident by certification tags applied to the jamb and leaf of each door:
NZS 4520 is referenced in the New Zealand Building Code Acceptable Solutions (Appendix C 6.1.1). NZ Fire Doors Limited fire doors have been successfully fire-tested in accordance with AS1530.4, as referenced in NZS 4520 and in Appendix C 5.1.1
Where fire rated laminated glass vision panels are fitted to fire doors manufactured by NZ Fire Doors Limited, the use of such glass is also within the prescription detailed in Certifire Certificate of Approval CF 862
In addition to the 15-year durability requirements of the New Zealand building code clause B2 DURABILITY, New Zealand Fire Doors also offer a warranty period of 1 year from date of installation, against defects in materials or workmanship.
NZ Fire Doors provide an extensive range of fire rated and non-fire rated door and window systems.
Product EnquiriesNew and updated architectural products, design solutions, inspiration, technical advice and more when you sign up for EBOSS.