You are using an outdated browser version not supported by this website.
Click here to upgrade your browser
5,288 products with technical literature, drawings and more from leading suppliers of NZ architectural materials.
Case studies, new products and product news from leading suppliers of NZ architectural materials.
Blogs for architectural specifiers, offering product, design and business advice.
Like many great things, the Elegance Range was born of a desire to make an existing product better. For years Allproof Industries has led the market with its range of shower wastes. Now a new look with sleek stainless steel construction updates the system for modern bathrooms.
Compatible with a range of Allproof flange systems including Allproof's standard LC flange, Cyclone floor waste solution and Revolver system.
Allproof floor waste products have been designed for compliance with the scope outlined in building codes listed above for internal floor drainage and to be installed as per published installation guides. For commercial and/or residential applications. Compatible with other AS/NZS and NZBC compliant DWV systems, waterproofing membrane systems and flooring systems.
NZBC G13/AS1 Foul water clause 1(b), 3.1(c) & (d) and clause 3.4 Floor Outlets: Allproof floor waste systems (water traps and grates) have been designed and manufactured to be compliant to all requirements set out in G13/AS1.
> The water seal in the gully prevents foul air and gases entering buildings,
> Grates are removable to access the system for maintenance and cleaning,
> Grates finish flush with the floor,
> Outlets exceed the minimum diameter.
Refer to install guides and specifications for further information.
NZBC G13/AS3 Foul water and AS/NZS 3500.2 clauses 4.6: Allproof floor waste systems have been designed to comply with all criteria outlined in AS/NZS 3500.2 and modifications covered in NZBC G13/AS3. Outlet connections designed to specifications in Appendix A of 3500.2. Gullies designed in accordance with requirements in clause 4.6.
AAS 3740 clause 3.14: Allproof floor waste systems have been designed to specifications and requirements set out in AS 3740 clause 3.14 for the membrane to drainage connection following figures 3.8 and 3.9.
B2/AS1 Durability: B2.3.1 - Allproof floor waste systems meet the requirements of B2.3.1 (a) not less than 50 years, (b) not less than 15 years and (c) not less than 5 years.
WaterMark Certificate of Conformity has been obtained on all relevant floor wate components for-
> AS1260 (WMKA 21800),
> WMTS-040 (WMKT 21223),
> and AS2887 (WM 74706).
A New Zealand owned company specialising in the manufacture of plumbing and drainage products and systems.
Product EnquiriesNew and updated architectural products, design solutions, inspiration, technical advice and more when you sign up for EBOSS.