You are using an outdated browser version not supported by this website.
Click here to upgrade your browser

InteriorInterior
MC760 Roofing and Wall Cladding System
Description

MC760 Roofing and External Wall Cladding system is comprised of a long run steel sheet with a 5 rib asymmetrical trapezoidal profile, along with associated design and installation information. 

Metalcraft fabricates the MC760 sheets from steel manufactured by New Zealand Steel. This steel is supplied with different protective coatings which are designed to withstand conditions in specific New Zealand Corrosion Zones. 

Key Features
  • Popular and versatile 5 rib trapezoidal roofing profile
  • MC760 offers the value of Corrugate, but suitable for low pitch options
  • Suitable for roofing, and horizontal or vertical cladding
  • Ideal for low pitch roofs (min 3°)
  • MC760 sheets are available in Colorsteel® Endura®, Galvsteel®, Colorsteel® Maxx®, and Zincalume®
  • MC760 sheets are available in the following sizes: 
    • Thicknesses: 0.4mm and 0.55mm
    • Width: Cover = 760mm Sheet = 810mm
Scope of Use

Metalcraft Roofing supply the MC760 system as a horizontal and vertical external wall cladding, and for roofs with a defined minimum pitch for 3 degrees, for use on commercial and residential buildings within the following scope:

Location:

  • In wind zones:
    • Up to and including Extra High as defined by NZS-3604:2011
    • Subject to specific engineering, if the engineer has satisfied themselves that the product, pitch and fixings will meet the conditions
  • In all climate zones as defined by NZS-3604:2011, subject to the limitations set out below
  • On buildings located within 1m of the relevant boundary, in respect of fire spread only

Building:

  • On new buildings that have been designed and constructed to comply with the NZ Building Code (NZBC) using timber or steel framing
  • On existing buildings using timber and steel framing where the designer and installer have satisfied themselves that the building is suitable for the intended building work
  • In conjunction with a vapour permeable building wrap that has a permeability of 36g/m2/day of a vapour resistance of no more than 500MNs/g
  • Can be used in conjunction with a potable water collection system
Limitations on Use

Location:

  • MC760 may be used as a roof cladding system in exposure zones B, C & D as defined in Sec 4, NZS3604:2011. For use in 'Microclimatic considerations,' (as defined in Sec 4.2.4) refer to Metalcraft Roofing
  • MC760 may be used as a wall cladding system in exposure zones B & C
  • Where MC760 is to be used in exposure Zone D, then only Colorsteel® Endura® or Colorsteel® Maxx® may be used

Building:

  • Where MC760 is used in an insulated building in conjunction with steel framing, a thermal break is required
  • Contact with other materials must be in accordance with Table 21 (E2/AS1), or compatible with the The New Zealand Metal Roofing Manufacturers Association Inc (NZMRM) Code Of Practice
  • Building height and design wind speed is limited by the MC760 design load span tables
  • Where it is used as a roof cladding, MC760 sheet lengths of ≤ 40m must be installed on a roof with a minimum pitch of 3°. MC760 sheet lengths of > 40m but ≤ 60m must be installed on a roof with a minimum pitch of 4°
  • When used horizontally or vertically as a wall cladding, MC760 must always be installed in conjunction with a drained cavity
Statement of Building Code Compliance

If designed, installed and maintained in accordance with all Metalcraft Roofing requirements, the MC760 Roofing and External Cladding system will comply with or contribute to compliance with the following provisions of the NZ Building Code:

  • B1 Structure: B1.3.1, B1.3.2, B1.3.3 (a, b, c, d, g, i)
  • B2 Durability: B2.3.1 (b)
  • C3 Fire Affecting Areas Beyond the Fire Source: C3.4(a), C3.5, C3.7 (a)
  • E2 External Moisture: E2.3.1, E2.3.2, E2.3.7 (a-c)
  • F2 Hazardous Building Materials: F2.3.1

See product technical statement for full information.

Other Performance Attributes
  • MC760 Roofing and External Cladding system will not contaminate potable water — AS/NZS 4020:2005
Documents
BPIR/PTS

02/2022

Loadspan Graph and Fixing Table
Fire Testing Document
CAD/PDF Link
Environmental Category Brochure
MC760
Colour Range
CAD/PDF Details
Commercial Horizontal Cladding Details
Commercial Horizontal Cladding Details DWG
Commercial Roof Details
Commercial Roof Details DWG
Commercial Roof Details DXF
Commercial Vertical Cladding Details
Commercial Vertical Cladding Details DWG
Commercial Vertical Cladding Details DXF
Residential Horizontal Cladding Details
Residential Horizontal Cladding Details DWG
Residential Horizontal Cladding Details DXF
Residential Roof Details
Residential Roof Details DWG
Residential Roof Details DXF
Residential Vertical Cladding Details
Residential Vertical Cladding Details DWG
Residential Vertical Cladding Details DXF
BIM
Commercial Horizontal Cladding Details RVT
Commercial Roof Details RVT
Commercial Vertical Cladding Details RVT
Residential Horizontal Cladding Details RVT
Residential Roof Details RVT
Residential Vertical Cladding Details RVT

Metalcraft Roofing are a privately owned building product rollformer and installer with an extensive range of longrun roofing profiles, lightweight metal tiles and rainwater system solutions.

Product Enquiries

News from Metalcraft Roofing

Modern, Innovative Learning at Lemonwood Grove School
Metalcraft Solar: Fully Integrated Solar Systems
Cedar and Deep Trough Combo Provides Eye-Catching Facade
Get a free weekly digest of essential news

New and updated architectural products, design solutions, inspiration, technical advice and more when you sign up for EBOSS.