GreenStuf Sound Solution Plus (ASB)
Description

Premium acoustic insulation blanket available in 50mm, 60mm, 70mm, 75mm, 90mm, and 120mm blanket

This product was known as ASB but was recently changed to Sound Solution® Plus.

Sound Solution® Plus is an acoustic insulation blanket that can be used as ceiling overlay to help make spaces quieter in commercial applications or for intertenancy walls to support privacy.

Key Features
  • Significantly reduces sound transfer in intertenancy walls
  • Most rolls are pre-cut to fit standard metal stud partition walls set at 600 centres to help make install nice and easy
  • Independently tested & assessed achieving NZBC Fire Standards
  • Thermally bonded without harmful chemicals
  • Safe and easy to install without PPE
  • Made locally in New Zealand
Declare LBC Red List Free
Declare LBC Red List Free
Green Tag Certified
Green Tag Certified
Recyclable Content (Post-Consumer)
Post-Consumer Recyclable Content
Recycled Content (Pre-Consumer)
Pre-Consumer Recycled Content
NZ Made
NZ Made
NZ-Owned Business
NZ-Owned Business
Scope of Use
  • Application: Acoustic insulation
  • Fitting: Internal walls, ceiling overlays, inter-tenancy wall systems & mid-floors

GreenStuf Sound Solution can be used in timber framed walls and mid-floor cavities for reducing airborne sound transfer. GreenStuf Sound Solution reduces resonating noise in the construction cavity thereby reducing the sound energy transferred from one side to the other. Further improvements can be achieved by using acoustically rated plasterboard, multiple layers of plasterboard, or by isolating the plasterboard from the stud. 

Product Name
Thickness
Width
Type
Nominal grams per m2 (GSM)
Nominal Density (kg/m3)
Sound Solution Plus 50 (ASB 3)
50mm
600mm
Roll
735
14.7
Sound Solution Plus 60 (ASB 4)
60mm
600mm
Roll
750
12.5
Sound Solution Plus 70 (ASB 5)
70mm
600mm
Roll
900
12.9
Sound Solution Plus 75 (ASB 6)
75mm
600mm
Roll
1105
14.7
Sound Solution Plus 90 (IT)
90mm
560mm
Roll
1325
14.7
Sound Solution Plus 120 (ASB 7)
120mm
600mm
Roll
1680
14
Limitations on Use

The New Zealand Building Code (NZBC) sets out minimum performance ratings for inter-tenancy walls and floor-ceiling construction. The performance of a construction system relies on the design, materials and installation. Acoustic design for NZBC compliance requires specialist design considerations. To ensure Building Code compliance, architects and building designers are advised to consult an engineer or the relevant NZ standards before specifying acoustic insulation products. For information and assistance please contact a GreenStuf account manager.

Statement of Building Code Compliance

NZBC Compliance: When installed in accordance with the manufacturer’s instructions, GreenStuf insulation will satisfy the 50 year durability clause NZBC B2.3.1 (a). GreenStuf meets the relevant clauses of NZBC E3 Internal Moisture, F2 Hazardous Building Materials, and may contribute to meeting H1 Energy Efficiency, and G6 Acoustic Design requirements. 

H1 Energy Efficiency: This product will contribute to a building meeting building code Clause H1. All GreenStuf thermal insulation is created to meet with MBIE's new changes.

Fire Regulations: GreenStuf insulation may not be suitable for all applications, as stipulated in the NZBC. Please consult a fire engineer when specifying GreenStuf insulation or contact a GreenStuf account manager for further information. 

Acoustic Performance: The Sound Transmission Class (STC) is the industry accepted means of determining a material or assembly’s ability to resist airborne sound transfer. A higher STC rating blocks more noise from transmitting through a construction system. 

GreenStuf Sound Solution will assist in reducing the resonating noise inside the construction cavity. Typical improvement in sound transmission loss through walls with the use of GreenStuf Sound Solution is an increase of 6-7 STC points, effectively reducing loud voices to a slight murmur. 

Typical improvement in sound transmission loss through a common residential mid-floor construction with the use of Sound Solution is an increase of 5-7 STC points. 

Thermal Performance: GreenStuf Sound Solution has been laboratory tested to ASTM C518-10 using the procedures of ASTM C653-97(2002) including the modifications specified in AS/NZS 4859.1:2002. 

Material Thermal Resistance: 1.8m² K/W @ 15ºC Product R-Value: R1.8 @ 90mm All products are guaranteed by GreenStuf to meet stated thermal performance values. 

Durability: GreenStuf has a 50 Year Durability Warranty. 

Moisture: GreenStuf is not affected by moisture. Exposure to an atmosphere of 50°C at 90% relative humidity for four days showed moisture absorption by weight of less than 0.03%. 

Hazardous Building Materials: GreenStuf is non-hazardous.

Documents
BPIR Document
Material Data Sheet
Sound Solution Plus (ASB) Data Sheet
Durability Warranty
Existing Homes
GIB Noise Control Systems
GreenStuf Guide
H1 Compliance Toolkit
Insulating Safely Around Downlights
Residential Guide
GreenStuf Product List
Sound Solution® Plus Product Page

GreenStuf thermal and acoustic insulation is made from 100% polyester fibre, with a focus on zero waste and recyclability, it contributes to improved air quality, and is safe to touch.

Product Enquiries

News from GreenStuf

Introducing GreenStuf ADW and ARD: Premium Ducting Insulation Solutions NEW
GreenStuf Takeback Programme: Circularity in Construction
The GreenStuf Advantage: How Sustainability, Quality, Safety, and Innovation Redefine Insulation Excellence
Get a free weekly digest of essential news

New and updated architectural products, design solutions, inspiration, technical advice and more when you sign up for EBOSS.